首页    期刊浏览 2024年11月23日 星期六
登录注册

文章基本信息

  • 标题:A Study on adverse effect of smoke/flue on lung functions of glass factory workers of Firozabad district
  • 本地全文:下载
  • 作者:Santosh Kumar Sant ; Abid Ahsan ; Kirti Jaiswal
  • 期刊名称:Indian Journal of Community Health
  • 印刷版ISSN:2248-9509
  • 出版年度:2014
  • 卷号:26
  • 期号:1
  • 页码:41-43
  • 语种:English
  • 出版社:Indian Association of Preventive and Social Medicine Uttar Pradesh and Uttarakhand Chapter
  • 摘要:The pulmonary function impairment is the most common respiratory problem in industrial plants and their vicinity. Therefore, the purpose was to study the effects of furnace smoke and flue and its duration of exposure on lung function. This was a matched cross-sectional study of Spirometry in 100 bangle workers with age range 20 – 60 years, who worked without the benefit of smoke control ventilation or respiratory protective devices. Pulmonary function test was performed by using Digital Spirometer (Spiro-excel). Significant reduction was observed in the mean values of Forced Vital Capacity (FVC), Forced Expiratory Volume in one second (FEV1), Forced Expiratory Ratio (FEV1/FVC), Forced Expiratory Flow (25%-75%) and Peak Expiratory Flow Rate (PEFR) in bangle workers relative to their matched controls. This impairment was increased with the duration of exposure to fumes in bangle industries. It is concluded that lung function in bangle workers is impaired and stratification of results shows a dose-response effect of years of smoke and flue exposure on lung function.
  • 其他摘要:The pulmonary function impairment is the most common respiratory problem in industrial plants and their vicinity. Therefore, the purpose was to study the effects of furnace smoke and flue and its duration of exposure on lung function. This was a matched cross-sectional study of Spirometry in 100 bangle workers with age range 20 – 60 years, who worked without the benefit of smoke control ventilation or respiratory protective devices. Pulmonary function test was performed by using Digital Spirometer (Spiro-excel). Significant reduction was observed in the mean values of Forced Vital Capacity (FVC), Forced Expiratory Volume in one second (FEV1), Forced Expiratory Ratio (FEV1/FVC), Forced Expiratory Flow (25%-75%) and Peak Expiratory Flow Rate (PEFR) in bangle workers relative to their matched controls. This impairment was increased with the duration of exposure to fumes in bangle industries. It is concluded that lung function in bangle workers is impaired and stratification of results shows a dose-response effect of years of smoke and flue exposure on lung function.
  • 关键词:Keywords:Occupational hazards, pulmonary function, bangle workers,Forced Vital Capacity (FVC), Forced Expiratory Volume in First second(FEV1),Forced Expiratory Ratio (FEV1/FVC), Forced Expiratory Flow Between 25-75% (FEF 25-75), Peak Expiratory Flow Rate
国家哲学社会科学文献中心版权所有