首页    期刊浏览 2024年07月06日 星期六
登录注册

文章基本信息

  • 标题:Observational calibration of the projection factor of Cepheids - II. Application to nine Cepheids with HST/FGS parallax measurements
  • 其他标题:II. Application to nine Cepheids with HST/FGS parallax measurements⋆
  • 本地全文:下载
  • 作者:J. Breitfelder ; J. Breitfelder ; A. Mérand
  • 期刊名称:Astronomy & Astrophysics
  • 印刷版ISSN:0004-6361
  • 电子版ISSN:1432-0746
  • 出版年度:2016
  • 卷号:587
  • 页码:1-18
  • DOI:10.1051/0004-6361/201527030
  • 语种:English
  • 出版社:EDP Sciences
  • 摘要:Context. The distance to pulsating stars is classically estimated using the parallax-of-pulsation (PoP) method, which combines spectroscopic radial velocity (RV) measurements and angular diameter (AD) estimates to derive the distance of the star. A particularly important application of this method is the determination of Cepheid distances in view of the calibration of their distance scale. However, the conversion of radial to pulsational velocities in the PoP method relies on a poorly calibrated parameter, the projection factor (p-factor). Aims. We aim to measure empirically the value of the p-factors of a homogeneous sample of nine bright Galactic Cepheids for which trigonometric parallaxes were measured with the Hubble Space Telescope (HST) Fine Guidance Sensor. Methods. We use the SPIPS algorithm, a robust implementation of the PoP method that combines photometry, interferometry, and radial velocity measurements in a global modeling of the pulsation of the star. We obtained new interferometric angular diameter measurements using the PIONIER instrument at the Very Large Telescope Interferometer (VLTI), completed by data from the literature. Using the known distance as an input, we derive the value of the p-factor of the nine stars of our sample and study its dependence with the pulsation period. Results. We find the following p-factors: p = 1.20 ± 0.12 for RT Aur, p = 1.48 ± 0.18 for T Vul, p = 1.14 ± 0.10 for FF Aql, p = 1.31 ± 0.19 for Y Sgr, p = 1.39 ± 0.09 for X Sgr, p = 1.35 ± 0.13 for W Sgr, p = 1.36 ± 0.08 for β Dor, p = 1.41 ± 0.10 for ζ Gem, and p = 1.23 ± 0.12 for ℓ Car. Conclusions. The values of the p-factors that we obtain are consistently close to p = 1.324 ± 0.024. We observe some dispersion around this average value, but the observed distribution is statistically consistent with a constant value of the p-factor as a function of the pulsation period (χ2 = 0.669). The error budget of our determination of the p-factor values is presently dominated by the uncertainty on the parallax, a limitation that will soon be waived by Gaia.
  • 关键词:stars: variables: Cepheids;techniques: interferometric;methods: observational;stars: distances
国家哲学社会科学文献中心版权所有