摘要:In order to express outlet deviation angle of turbomachine stator, outlet deviation angle dominantly expressed by fluid velocity distribution was derived based on equivalent moment of momentum under the condition of certain CFD simulation design parameters. On this basis, response surface function of outlet deviation angle was constructed by CFD simulation data of orthogonal experiment. The validity of the response surface function was proved by CFD simulation data of confirmatory models. An effective method is provided for calculating outlet deviation angle of turbomachine stator.
关键词:Equivalent moment of momentum principle;outlet deviation angle;quantitative expression;turbomachine stator;computational fluid dynamic (CFD)