摘要:The mathematical models of heat and mass transfer in the packing columns (PC) and tubular absorbers (TA) with the square and triangular tube arrangement along their axes are derived for fully open flow cross-section of the device and closed tube space. The paper shows the energy advantage of TA in comparison with PC with the same extraction efficiencies of target gas component from the stream.