  • 标题:Using an accelerometer for analyzing a reach-to-grasp movement after stroke
  • 本地全文:下载
  • 作者:Stella Maris Michaelsen ; Raquel Pinheiro Gomes ; Aline Perão Marques
  • 期刊名称:Motriz. Journal of Physical Education. UNESP
  • 印刷版ISSN:1980-6574
  • 出版年度:2013
  • 卷号:19
  • 期号:4
  • 页码:746-752
  • DOI:10.5016/6849
  • 语种:Portuguese
  • 出版社:UNESP - São Paulo State University
  • 摘要:The purpose of this study was using an accelerometer to access the kinematics of reach-to-grasp movements in subjects with hemiparesis. Eight subjects (59.4 ± 6.9 years old) with chronic hemiparesis (50.9 ± 25.8 months post-stroke) participated in this study. Kinematic assessment was performed using a triaxial accelerometer (EMG Systems, Brazil) attached to the subjects' forearm. Ten reach-to-grasp movements of grabbing a 500ml-size bottle were performed by the subjects with the paretic and the non-paretic upper limbs (ULs). The following spacetemporal variables were calculated and used to compare the paretic and non-paretic ULs: movement time (MT), time to reach the peak velocity, absolute and relative (TPV and TPV%MT), relative deceleration duration (DEC%MT), time to peak acceleration (TPA) and peak hand acceleration (PA). Movements were slower in the paretic UL with increased MT, TPA and DEC. The accelerometer allowed to identify of changes in reaching-to-grasp movements of subjects with hemiparesis. When complex systems are not available, accelerometers can be an alternative to measure UL movements.
  • 其他摘要:The purpose of this study was using an accelerometer to access the kinematics of reach-to-grasp movements in subjects with hemiparesis. Eight subjects (59.4 ± 6.9 years old) with chronic hemiparesis (50.9 ± 25.8 months post-stroke) participated in this study. Kinematic assessment was performed using a triaxial accelerometer (EMG Systems, Brazil) attached to the subjects' forearm. Ten reach-to-grasp movements of grabbing a 500ml-size bottle were performed by the subjects with the paretic and the non-paretic upper limbs (ULs). The following spacetemporal variables were calculated and used to compare the paretic and non-paretic ULs: movement time (MT), time to reach the peak velocity, absolute and relative (TPV and TPV%MT), relative deceleration duration (DEC%MT), time to peak acceleration (TPA) and peak hand acceleration (PA). Movements were slower in the paretic UL with increased MT, TPA and DEC. The accelerometer allowed to identify of changes in reaching-to-grasp movements of subjects with hemiparesis. When complex systems are not available, accelerometers can be an alternative to measure UL movements.
  • 关键词:Kinematic. Movement. Upper limb. Hemiparesis.;Cinemática. Movimento. Membro superior. Hemiparesia.
  • 其他关键词:Kinematic. Movement. Upper limb. Hemiparesis.;Movement Sciences