摘要:Onsite application of oxygen supply in domestic wastewater system may be influenced by several factors that can inhibit the oxidation and nitrification processes. In this study, the influence of aeration rate on theJohkasouperformance was focused using twoJohkasoufacilities serving up to five persons household. In theJohkasouA (JO-A) system, we increased the aeration rate from 30 to 63 L.min-1whereas, in theJohkasouB (JO-B), it was decreased from 59 to 34 L.min-1. Water and sludge samples were collected from the anaerobic-anoxic-oxic zones before and after adjustment of the aeration rate measured for organic matters and nitrogen parameters. Increasing the aeration rate in JO-A resulted in a high removal of organic matter (82.5%) and nitrogen (60.3%) compared to decreasing of aeration rate in JO-B (52.0% and 33.0%, respectively). Simultaneous nitrification and denitrification (SND) exhibited a maximum percentage when the aeration rate was increased compared to decreasing of aeration rate. These results indicate that application of a high aeration rate increases removal of organic matter and nitrogen and enhances ammonia transformation. It is therefore recommended to apply high aeration rates inJohkasousystem.