摘要:The underground temperature at a depth of about 3–4 m is almost constant all the year round. In summer, the underground temperature is lower than the ambient temperature, but in winter it is vice versa. This potentiality is considered for greenhouse cooling and heating by using an earth-to-air heat exchanger (EAHE). This paper considers the effects of two parameters as independent variables including the area of greenhouse and the percentage of vegetation coverage inside the greenhouse on the performance of an EAHE system during both cooling and heating modes. The inside temperature, the thermal energy exchange and the coefficient of performance (COP) of the system were considered as dependent variables. The results showed that both greenhouse area and the percentage of vegetation coverage inside the greenhouse had significant effects on the performance of the EAHE system during both cooling and heating modes. However, the COP of the EAHE system was higher in the cooling mode (4.32) than during the heating mode (1.01). The percentage of vegetation coverage negatively affected the performance of the EAHE system in the cooling mode. However, the performance of the EAHE system improved with the increase in the percentage of vegetation coverage during the heating mode.