首页    期刊浏览 2025年06月26日 星期四
登录注册

文章基本信息

  • 标题:Heat Transfer and Friction Factor Correlationsfor Rectangular Solar Air Heater DuctHaving 60° Inclined Continuous DiscreteRib Arrangement
  • 本地全文:下载
  • 作者:Thakur Sanjay Kumar ; Vijay Mittal ; N. S. Thakur
  • 期刊名称:Current Journal of Applied Science and Technology
  • 印刷版ISSN:2457-1024
  • 出版年度:2011
  • 卷号:1
  • 期号:3
  • 页码:67-93
  • 语种:English
  • 出版社:Sciencedomain International
  • 摘要:The heat transfer coefficient between the absorber plate and air can be considerably increased by using artificial roughness on the underside of the absorber plate of the solar air heater. An experimental study has been carried out for enhancement of heat transfer coefficient of a solar air heater having roughened air duct provided with artificial roughness in the form 60° inclined discrete rib. Increment in friction factor by provided with such artificial roughness element has also been studied. The effect of system parameters such as relative roughness height (e/D), relative roughness pitch (P/e) and relative gap position (d/W) have been studied on Nusselt number (Nu) and friction factor (f) with relative gap width (g/e) 1 and Reynolds number (Re) varied from 4105 to 20526. Considerably enhancement in heat transfer coefficient has been achieved with such roughness element. Using experimental data correlations for Nusselt number and friction factor have also been developed for such solar air heaters, which gives a good agreement between predicted values and experimental values of Nusselt number and friction factor.
  • 关键词:Solar air heater;artificial roughness;Nusselt number;Friction factor