首页    期刊浏览 2024年10月05日 星期六
登录注册

文章基本信息

  • 标题:MEASUREMENTS OF MERCURY ASSOCIATED WITH AIRBORNE PARTICLE MATTER: USE OF TWO SAMPLING DEVICES
  • 本地全文:下载
  • 作者:Julia Lu ; Zia Mahmood Siddiqi
  • 期刊名称:Fresenius Environmental Bulletin
  • 印刷版ISSN:1018-4619
  • 出版年度:2015
  • 卷号:24
  • 期号:4
  • 页码:1326-1332
  • 语种:English
  • 出版社:PSP Publishing
  • 摘要:Two different sampling devices, quartz mini-sampler with quartz fiber filter (6 mm diameter) [1] and Teflon openface sampler with quartz fiber filter (47mm diameter) were compared for collecting airborne particulate matter for the analysis of total filterable mercury (TFM) in the atmosphere. Thermal pyrolysis was used for sample preparation and Cold Vapor Atomic Fluorescence Spectrometry (CVAFS) for mercury detection and quantification. The mini-sampler has a better time resolution (daily) than the Teflon openface sampler (normally one week integration time). The latter has the advantages of better precision, convenience, time saving and cost effectiveness. The comparative measurements of TFM in the ambient atmosphere have been done simultaneously using the two methods in downtown Toronto from June- December 2004. It is observed that, under the identical weather and analysis conditions, the weekly concentration of TFM ranged from 22.9 10.6 to 56.0  52.2 pg m-3 and 20.1  1.6 to 63.0  19.1 pg m-3 by mini-samplers and open-face sampler, respectively. Thus the results showed a good agreement between the two sampling methods.
  • 关键词:Methods inter-comparison; Mini-sampler; Teflon open-face sampler; Total filterable mercury; Atmospheric mercury