摘要:AbstractGeneralization of PID controllers depending on the plant relative degree is addressed in the paper. The consecutive compensator approach is redesigned in the state-space representation and augmented with the integral loop and anti-windup scheme. The stability of the closed-loop system is proved. Efficiency of the proposed approach is illustrated by the experiments carried out using the 2-DOF indoor quadcopter testbed.