摘要:We use PVsyst software to simulate and calculate the first year electricity generation of 4 MW distributed photovoltaic power generation project. In order to analyze and select the suitable power plant operation mode, the total generating capacity of photovoltaic power station in 25 years has been estimated by using component attenuation of 25 years. This research reports on the findings shown by PVsyst software that evaluates the economy aspects brought by two kinds of operation modes which are full grid access mode and spontaneous use of residual power grid access mode. The research content has reference value for the construction of roof distributed photovoltaic power station in China.