首页    期刊浏览 2024年10月05日 星期六
登录注册

文章基本信息

  • 标题:Rigid External Distractors in Midface Fractures: A Review of Relevant and Related Literature
  • 本地全文:下载
  • 作者:Zachary Gala ; Jordan Halsey ; Samuel Kogan
  • 期刊名称:ePlasty: Open Access Journal of Plastic and Reconstructive Surgery
  • 印刷版ISSN:1937-5719
  • 出版年度:2020
  • 卷号:20
  • 语种:English
  • 出版社:Open Science Co. LLC
  • 摘要:Introduction: Literature discussing the use of rigid external distraction devices in midfacial trauma is limited. Rigid external distraction devices have been described for use in craniofacial surgery, allowing for distraction and stabilization of bony segments. In complex facial trauma, bony fragments are often comminuted and unstable, making traditional approaches with internal fixation difficult. Moreover, these approaches require subperiosteal dissection, limiting blood supply that is important for bone healing. Objective: The goal of this study was to evaluate the role of rigid external distraction devices for the treatment of complex facial trauma. Methods: We performed a literature review of rigid external distraction devices, as relevant both for facial trauma and for other craniofacial indications, to better elucidate their use and efficacy in complex facial fractures. Results: The review revealed only 2 articles explicitly describing rigid external distraction devices for facial trauma, while 6 other articles describing its use for other craniofacial cases. An important benefit associated with the use of rigid external distraction devices is their ability to provide controlled traction of bony segments while also allowing for movement as needed for fracture reduction. Various articles describe performing internal fixation following rigid external distraction device usage, while others emphasize that internal fixation is not necessarily indicated if the rigid external distraction device is left intact long enough to ensure bony healing. One potential setback described is unfamiliarity with using the rigid external distraction device, which can preclude its use by many surgeons. In addition, the literature review did not provide any uniform guidelines or recommendations about how long rigid external distraction devices should remain intact. Conclusion: Based on relevant literature, rigid external distraction devices have been shown to be useful in the stabilization and treatment of complex facial fractures. Further studies should be conducted to better elucidate the specific indications for rigid external distraction devices in complex facial trauma.
国家哲学社会科学文献中心版权所有