摘要:The objective of this study was to propose a new method for facilitating needle-beam alignment ultrasound-guided in-plane catheterization of the subclavian vein (SCV). Three hundred patients were recruited, and ultrasound examination of the SCV was performed. Then, the patients were divided into two groups and SCV catheterization was performed: ultrasound-guided catheterization with the aiming method (group A) and ultrasound-guided catheterization with needle guide (group NG). The success rate, insertion time, number of skin breaks, number of needle redirections, needle visibility and rate of mechanical complications were documented and compared for each procedure. To depict the optimum long-axis view of the SCV, there was a 30° ± 7.3° angle (rotation) between the long axis of the ultrasound probe and the clavicle, while there was a 39° ± 7.4° angle (tilt) between the ultrasound beam plane and the right chest wall. The aiming method was associated with fewer skin breaks [(mean (IQR): 1 (1–1) times
vs 1 (1–2) times,
P = 0.009