首页    期刊浏览 2024年07月09日 星期二
登录注册

文章基本信息

  • 标题:Failure Analysis and Protection of Oxygen Corrosion of Reheater Tube in a Power plant
  • 本地全文:下载
  • 作者:Chao Yang ; Xiuneng Li ; Yunan Wang
  • 期刊名称:E3S Web of Conferences
  • 印刷版ISSN:2267-1242
  • 电子版ISSN:2267-1242
  • 出版年度:2021
  • 卷号:261
  • 页码:1-5
  • DOI:10.1051/e3sconf/202126102027
  • 语种:English
  • 出版社:EDP Sciences
  • 摘要:The failure analysis of reheater tubes were analyzed by means of alloy composition analysis, metallographic structure analysis, mechanical properties analysis and oxide composition analysis. The results showed: The alloy composition meets the requirements of 12Cr1MoV standard. No abnormality was observed in metallographic structure. Mechanical properties qualified. Oxide components are mainly O and Fe. Comprehensive analysis shows that The main reason of reheater tube failure is oxygen corrosion, which caused thinning of the reheater tube wall, leading to leakage accident. Suggestions for subsequent protection are put forward.
国家哲学社会科学文献中心版权所有