  • 摘要:The aim of this study was to determine the effect of orifice diameter (1.0,1.2,1.6,2.0 and 2.4 mm),core (four types) and operational spray pressure (200,400,600,800 and 1200 kPa) variables on spray angle in hollow-cone nozzles produced from polyacetal (POM) material.The results of the variance analysis showed that the effect of nozzle orifice diameter,core and spray pressure variables on spray angle was very significant statistically.The highest spray angle was measured at the nozzle with large orifice diameter.For nozzle discs with the orifice di-ameters of 1.0 mm,1.2 mm,1.6 mm,2.0 mm,and 2.4 mm at the spray pressure level of 300 kPa,the spray angle varied between 49°-60°,60°-72°,74°-85°,80°-97° and 89°-101°,respectively.After a cer-tain pressure level,the spray angle varied within a stable range.The lowest spray pressure at which spray angle remains stable was determined to be 600 kPa in a nozzle with the orifice diameter ofl .0 mm,while it was determined to be 400 kPa in nozzles with the orifice diameters of 1.2 mm and 1.6 mm,and 200 kPa in nozzles with the orifice diameters of 2.0 mm and 2.4 mm.
  • 关键词:Hollow cone nozzle;Flow rate;Spray angle;Spray nozzle;Spray pressure