期刊名称:Current Journal of Applied Science and Technology
印刷版ISSN:2457-1024
出版年度:2021
卷号:40
期号:22
页码:1-7
DOI:10.9734/cjast/2021/v40i2231474
语种:English
出版社:Sciencedomain International
摘要:A study of evaporative cool hydroponic chamber was made with respect to its cooling and qualitative evaluation for growth of maize. The daily average temperature and RH range of 35.5 to 36.1 0C and 37–77% respectively were observed under Evaporative Cool Hydroponic Chamber (ECHC). The cooling efficiency of ECHC varied from 57.61% to 83.33% with an average value of 74.06%. Fresh biomass yield of fodder maize was observed as 1.2kg/ft2 of tray area. Crude protein and crude fibre on dry matter basis of hydroponic maize fodder ranged from 13.1-13.08% and 15.30-15.31% respectively. The ECHC can be used as an alternative of high cost hydroponic fodder machines which can be locally fabricated and operated by semi-skilled manpower.