标题:Evaluation of three different laboratory methods to detect preformed human leukocyte antigen antibodies in a South African kidney transplant population
摘要:Background
Anti-human leukocyte antigen antibodies (anti-HLA) play a crucial role in graft. Detection of anti-HLA, both pre- and post-transplant is a crucial investigation in clinical organ transplantation.
Objectives
Three methodologies for the detection of lymphocytotoxic antibodies were compared to establish which of these is best suited to optimise pre-transplant donor-recipient matching.
Methods
Serum samples from 15 renal transplant patients were tested for the presence of anti-HLA by i) cytotoxic-dependent cross-match (CDCXM), ii) flow cytometric cross-match (FCXM) and iii) Luminex-based donor specific antibody cross-match (DSAXM) method, Confirmatory tests for the presence of preformed HLA antibodies were tested using Luminex methodology.
Results
Two (13%) of the 15 patients had positive HLA Class I antibodies (Ab) using all 3 methods. An additional 2 HLA Class I Ab were identified with FCXM/CDCXM. DSAXM identified 1 HLA Class I positive, not indicated by CDCXM/FCXM.
High HLA Class II positivity (40%), identified by CDCXM, while DSAXM and FCXM identified two and one patients, respectively. CDCXM produced 4 false-positive results confirmed by lymphocyte single antigen (LSA) assay.
Conclusions
The DSAXM method appears to add value in pre-transplantation screening to identify pre-sensitised patients that may not reject the donor graft due to the absence of donor-specific antibodies.
关键词:enPreformed human leukocyte;antigen antibodies;kidney transplant;population;South Africa