摘要:Even a tiny functioning pituitary adenoma could cause symptoms; hence, accurate diagnosis and treatment are crucial for management. However, it is difficult to diagnose a small pituitary adenoma using conventional MR sequence. Deep learning-based reconstruction (DLR) using magnetic resonance imaging (MRI) enables high-resolution thin-section imaging with noise reduction. In the present single-institution retrospective study of 201 patients, conducted between August 2019 and October 2020, we compared the performance of 1 mm DLR MRI with that of 3 mm routine MRI, using a combined imaging protocol to detect and delineate pituitary adenoma. Four readers assessed the adenomas in a pairwise fashion, and diagnostic performance and image preferences were compared between inexperienced and experienced readers. The signal-to-noise ratio (SNR) was quantitatively assessed. New detection of adenoma, achieved using 1 mm DLR MRI, was not visualised using 3 mm routine MRI (overall: 6.5% [13/201