首页    期刊浏览 2024年12月02日 星期一
登录注册

文章基本信息

  • 标题:A simple method for getting standard error on the ratiometric calcium estimator
  • 本地全文:下载
  • 作者:Simon Hess ; Christophe Pouzat ; Peter Kloppenburg
  • 期刊名称:MethodsX
  • 印刷版ISSN:2215-0161
  • 电子版ISSN:2215-0161
  • 出版年度:2021
  • 卷号:8
  • 页码:1-12
  • DOI:10.1016/j.mex.2021.101548
  • 语种:English
  • 出版社:Elsevier
  • 摘要:Graphical abstractHow to get error bars on the ratiometric calcium estimator? The two measurements areas (region of interest, ROI, on the cell body and background measurement region, BMR, outside of the cell) are displayed on the frame corresponding to one actual experiment. Two measurements, one following an excitation at 340 nm and the other following an excitation at 380 nm are performed (at each ’time point’) from each region. The result is a set of four measures: adu340(from the ROI), adu340,B(from the BMR), adu380and adu380,B.. The fact that the measurements as well as the subsequent quantities derived from them are random variable realization is conveyed throughout the figure by the use of Gaussian probability densities. The densities from the BMR are ’tighter’ because there are much more pixels in the BMR than in the ROI (the standard deviations of the densities shown on this figure have been enlarged for clarity, but their relative size has been preserved, the horizontal axis in black always starts at 0). The key result of the paper is that the standard deviation of the four Gaussian densities corresponding to the raw data (bottom of the figure) can be reliably estimated from the data alone,egσ380≈Gadu380+V, whereVis the product of the CCD chip gain squared by the number of pixels in the ROI by the CCD chip read-out variance. The paper explains how to compute the standard deviation of the derived distributions obtained at each step of the calcium concentration estimation.Display OmittedAbstractThe ratiometric fluorescent calcium indicator Fura-2 plays a fundamental role in the investigation of cellular calcium dynamics. Despite of its widespread use in the last 30 years, only one publication (Joucla et al., 2010)) proposed a way of obtaining confidence intervals on fitted calcium dynamic model parameters from single ‘calcium transients’. Shortcomings of this approach are its requirement for a ‘3 wavelengths’ protocol (excitation at 340 and 380 nm as usual plus at 360 nm, the isosbestic point) as well as the need for an autofluorence / background fluorescence model at each wavelength. Here, we propose a simpler method that eliminates both shortcommings:1.a precise estimation of the standard errors of the raw data is obtained first,2.the standard error of the ratiometric calcium estimator (a function of the raw data values) is derived using both the propagation of uncertainty and a Monte-Carlo method.Once meaningful standard errors for calcium estimates are available, standard errors on fitted model parameters follow directly from the use of nonlinear least-squares optimization algorithms.
  • 关键词:Calcium measurements;Fura-2;Propagation of uncertainty;Propagation of errors;Monte-Carlo method;Reproducible research
国家哲学社会科学文献中心版权所有