首页    期刊浏览 2025年07月12日 星期六
登录注册

文章基本信息

  • 标题:Thermal effect of a fire on a steel beam with corrugated wall with fireproof mineral-wool cladding
  • 本地全文:下载
  • 作者:Valeriia Nekora ; Stanislav Sidnei ; Taras Shnal
  • 期刊名称:Eastern-European Journal of Enterprise Technologies
  • 印刷版ISSN:1729-3774
  • 电子版ISSN:1729-4061
  • 出版年度:2021
  • 卷号:5
  • 期号:1
  • 页码:24-32
  • DOI:10.15587/1729-4061.2021.241268
  • 语种:English
  • 出版社:PC Technology Center
  • 摘要:This paper reports a study into the possibility of applying a simplified approach, recommended by standards for conventional steel beams, to determine the heating temperature under the conditions of a fire in relation to steel I-beams with a corrugated wall. The research is predetermined by the limitation of methods that make it possible to determine the heating temperature of this type of beam in a fire using engineering methods with a small amount of calculations.Technical data on steel beams with cladding have been considered for calculation, the features of heat impact of fire on them have been analyzed, a calculation procedure has been devised, the estimation schemes have been built, and the calculations have been performed. Data on the temperature distribution in the cross-sections of beams with and without cladding were obtained by using a simplified method recommended by standards and the refined method based on a finite-element method.Mathematical models have been constructed for calculations that describe the effect of a standard temperature regime of fire on the distribution of temperature in each?minute in the cross-sections of steel beams with and without cladding. The models have been described on the basis of the differential equation of thermal conductivity, boundary conditions of the third kind, which take into consideration convective and radiant heat transfer.It was established that the?mineral wool cladding of the beam with a corrugated wall is a reliable fire protection agent. The heating temperature of the beam does not reach a critical value of 500?°C in 60?minutes, which provides the class of this beam with the most stringent requirements for its fire resistance in accordance with the classification in line with the acting norms in Ukraine.The simplified method, recommended by the current standards of the European Union and Ukraine, could be effectively used to analyze the fire resistance of these beams and is the basis of the procedure for the estimated assessment of the fire resistance of these structures.
  • 关键词:steel beam with corrugated wall;standard temperature regime;temperature distributions
国家哲学社会科学文献中心版权所有