首页    期刊浏览 2024年07月19日 星期五
登录注册

文章基本信息

  • 标题:Efficacy of Air Filtration and Education Interventions on Indoor Fine Particulate Matter and Child Lower Respiratory Tract Infections among Rural U.S. Homes Heated with Wood Stoves: Results from the KidsAIR Randomized Trial
  • 本地全文:下载
  • 作者:Ethan S. Walker ; Erin O. Semmens ; Annie Belcourt
  • 期刊名称:Environmental Health Perspectives
  • 印刷版ISSN:0091-6765
  • 电子版ISSN:1552-9924
  • 出版年度:2022
  • 卷号:130
  • 期号:4
  • DOI:10.1289/EHP9932
  • 语种:English
  • 出版社:OCR Subscription Services Inc
  • 摘要:Background: Millions of rural U.S. households are heated with wood stoves. Wood stove use can lead to high indoor concentrations of fine particulate matter [airborne particles ≤ 2.5 μ m in aerodynamic diameter ( PM 2.5 )] and is associated with lower respiratory tract infection (LRTI) in children. Objectives: We assessed the impact of low-cost educational and air filtration interventions on childhood LRTI and indoor PM 2.5 in rural U.S. homes with wood stoves. Methods: The Kids Air Quality Interventions for Reducing Respiratory Infections (KidsAIR) study was a parallel three-arm (education, portable air filtration unit, control), post-only randomized trial in households from Alaska, Montana, and Navajo Nation (Arizona and New Mexico) with a wood stove and one or more children < 5  years of age. We tracked LRTI cases for two consecutive winter seasons and measured indoor PM 2.5 over a 6-d period during the first winter. We assessed results using two analytical frameworks: a) intervention efficacy on LRTI and PM 2.5 (intent-to-treat), and b) association between PM 2.5 and LRTI (exposure–response). Results: There were 61 LRTI cases from 14,636 child-weeks of follow-up among 461 children. In the intent-to-treat analysis, children in the education arm [ odds ratio  ( OR ) = 0.98 ; 95% confidence interval (CI): 0.35, 2.72] and the filtration arm ( OR = 1.23 ; 95% CI: 0.46, 3.32) had similar odds of LRTI vs. control. Geometric mean PM 2.5 concentrations were similar to control in the education arm (11.77% higher; 95% CI: − 16.57 , 49.72) and air filtration arm (6.96% lower; 95% CI: − 30.50 , 24.55). In the exposure–response analysis, odds of LRTI were 1.45 times higher (95% CI: 1.02, 2.05) per interquartile range ( 25   μ g / m 3 ) increase in mean indoor PM 2.5 . Discussion: We did not observe meaningful differences in LRTI or indoor PM 2.5 in the air filtration or education arms compared with the control arm. Results from the exposure–response analysis provide further evidence that biomass air pollution adversely impacts childhood LRTI. Our results highlight the need for novel, effective intervention strategies in households heated with wood stoves. https://doi.org/10.1289/EHP9932
国家哲学社会科学文献中心版权所有