首页    期刊浏览 2024年11月27日 星期三
登录注册

文章基本信息

  • 标题:Thermal Comfort Properties of Cotton and Nonwoven Surgical Gowns with Dual Flunctional Finish
  • 本地全文:下载
  • 作者:Jeong-Sook Cho ; Shin-Ichi Tanabe ; Gilsoo Cho
  • 期刊名称:Journal of PHYSIOLOGICAL ANTHROPOLOGY and Applied Human Science
  • 印刷版ISSN:1345-3475
  • 出版年度:1997
  • 卷号:16
  • 期号:3
  • 页码:87-95
  • DOI:10.2114/jpa.16.87
  • 出版社:Japan Society of Physiological Anthropology
  • 摘要:The purpose of this study was to evaluate thermal comfort properties of surgical gowns made of dual functional finish cotton and nonwoven fabrics which have barrier properties of blood and micro-organism. Four types of surgical gowns, which were made of nonwoven fabrics with finish or without and were made of cotton with finish or without, were tested. The thermal insulations of four surgical gowns were measured with thermal manikin. Subjective experiments on thermal comfort, skin temperature and clothing microclimate were conducted. Six male subjects, between 26 and 28 years age old, participated in the wear trials tests. Typical activities for surgeons in the operation theater were simulated during the experimental sessions. Air temperature in a climate chamber was kept at 22°C and its humidity was 60%RH. Air velocity was controlled at less than 0.15 m/s. Inner radiant temperature was almost equal to the air temperature. Basic thermal insulation of the dual functional finished nonwoven surgical gown was 0.87 clo, which was slightly higher than that of untreated (0.84 clo). However, the skin temperature of the subject wearing. a dual functional finished surgical gown was significantly lower at P<.05. When the subject wears the dual functional finished gown, the amount of sweating was less than that when wearing untreated. Microclimate temperature and humidity of dual functional finished surgical gown were lower than untreated and it was statistically significant. There was no significant difference in subjective humid and overall comfort sensation between finished and untreated ones. Thermal sensation of dual functional finished one was significantly different from untreated one only during the first exercise. The results of this study indicate that the dual functional finish surgical gown allowed heat to be transferred from the skin of subject to the atmosphere better than untreated. The nonwoven surgical gown showed no difference in comfort properties from cotton one.
  • 关键词:surgical gown;thermal comfort;nonwoven;thermal insulation;dual functional finish
国家哲学社会科学文献中心版权所有