摘要:Technologically contaminated water, formed during processing of coal slurries, finds its application in modern technological cycles of coal enrichment. Limitation of use of untreated recycled water of coal concentration plants is caused by a high degree of its mineralization by various salts, presence of insoluble solid particles and presence of flotation reagents, coagulants and flocculants. Part of technical water purified from mineral and organic contaminants can be used in heating systems and heat exchange equipment of industrial enterprises, including the coal industry. For this purpose, it is necessary to reduce the scale-forming ability of service water (to reduce the content of soluble calcium and magnesium salts in water). One of the most effective and advanced methods is the stabilization treatment of water with an electric field. In addition, this method is environmentally safe, low-cost and simple. The article gives the foundation of the method of stabilization treatment of recycled water of concentrating plants by an electric field, a description of the methodology of the laboratory experiment for scaling reduction, and the analysis of the results.