首页    期刊浏览 2024年10月06日 星期日
登录注册

文章基本信息

  • 标题:Tri-Channel Electrochemical Immunobiosensor for Combined Detections of Multiple Exosome Biomarkers of Lung Cancer
  • 本地全文:下载
  • 作者:Cui Fan ; Bingyan Jiang ; Wenjia Shi
  • 期刊名称:Biosensors
  • 电子版ISSN:2079-6374
  • 出版年度:2022
  • 卷号:12
  • 期号:7
  • DOI:10.3390/bios12070435
  • 语种:English
  • 出版社:MDPI Publishing
  • 摘要:Current methods for the early diagnosis of cancer can be invasive and costly. In recent years, exosomes have been recognized as potential biomarkers for cancer diagnostics. The common methods for quantitative detection of exosomes, such as nanoparticle tracking analysis (NTA) and flow cytometry, rely on large-scale instruments and complex operation, with results not specific for cancer. Herein, we present a tri-channel electrochemical immunobiosensor for enzyme-free and label-free detecting carcino-embryonic antigen (CEA), neuron-specific enolase (NSE), and cytokeratin 19 fragments (Cyfra21-1) from exosomes for specific early diagnosis of lung cancer. The electrochemical immunobiosensor showed good selectivity and stability. Under optimum experimental conditions, the linear ranges were from 10 −3 to 10 ng/mL for CEA, 10 −4 to 10 2 ng/mL for NSE, and 10 −3 to 10 2 ng/mL for Cyfra21-1, and a detection limit down to 10 −4 ng/mL was achieved. Furthermore, we performed exosome analysis in three kinds of lung cancer. The results showed a distinct expression level of exosomal markers in different types. These works provide insight into a promising alternative for the quantification of exosomal markers in specific diseases in the following clinical bioassays.
  • 关键词:electrochemical immunobiosensor;exosome detection;multiple biomarkers;lung cancer
国家哲学社会科学文献中心版权所有