首页    期刊浏览 2024年09月19日 星期四
登录注册

文章基本信息

  • 标题:Use of the FloTrac/Vigileo SystemTM for Adequate Fluid Management in a Patient Undergoing Lobectomy for a Complex Type of Pulmonary Arteriovenous Fistula
  • 本地全文:下载
  • 作者:Takashi Tsunetoh ; Ryu Okutani ; Hirokatsu Toyoyama
  • 期刊名称:循環制御
  • 印刷版ISSN:0389-1844
  • 出版年度:2010
  • 卷号:31
  • 期号:1
  • 页码:49-54
  • DOI:10.11312/ccm.31.49
  • 出版社:Japan Society of Circulation Control in Medicine
  • 摘要:We report a case of a 15-year-old girl who underwent the left lower lobectomy for a complex type of pulmonary arteriovenous fistula, which caused a huge right-to-left shunt in the pulmonary circulation. During the operation with one-lung ventilation anesthesia, the right heart failure in company with severe hypoxemia or malignant ventricular arrhythmias, might be induced as the result of the sudden reduction of shunt flow. Furthermore, possible pulmonary edema due to ischemic reperfusion-like injury might be possible to develop by fluid overload, after the normal pulmonary perfusion restarted. FloTrac/Vigilleo SystemTM can provide useful hemodynamic parameters such as arterial pressure-based cardiac output and stroke volume variation based on the concept of fluid responsiveness. In our case, this system was successfully applied to achieve optimal cardiac preload for organ perfusion without transfusion and to prevent the right heart failure and pulmonary edema.
  • 关键词:pulmonary arteriovenous fistula ; FloTrac/Vigilleo SystemTM ; one-lung ventilation ; general anesthesia
国家哲学社会科学文献中心版权所有