首页    期刊浏览 2025年06月13日 星期五
登录注册

文章基本信息

  • 标题:Análisis de la transmitancia térmica y resistencia al impacto de los muros de quincha
  • 本地全文:下载
  • 作者:G. Cuitiño ; A. Esteves ; G. Maldonado
  • 期刊名称:Informes de la Construcción
  • 印刷版ISSN:0020-0883
  • 电子版ISSN:1988-3234
  • 出版年度:2015
  • 卷号:67
  • 期号:537
  • 页码:1-11
  • DOI:10.3989/ic.12.082
  • 出版社:Consejo Superior de Investigaciones Científicas
  • 摘要:Wattle construction is a mixed technique used on walls and that belong to the frameworks family. It is constructed with a structural frame (wood or bamboo) filled in with a mixture of clay mud in a plastic state and vegetable fiber. In this paper thermal transmittance and soft shock resistance had been studied, thermal transmittance had been measured with wattle samples of 0.10 m thickness, and result in 2.64 W/m 2 K and with the addition of expanded polystyrene sheet of 5 mm thicknees inside the panel, the transmittance was 2.02 W/m 2 K. These values are batter than a brick wall of 0.20 m thick with a finish plaster on both sides of the wall, whose value is 4.13 W/m 2 K. For impact resistance, panels were constructed and tested to soft shock, on 1:1 scale. The permanent deformation in all cases was less than 3.6 mm required by the current standard. This implies that there was no appreciable deformations suffered enclosures providing security to a home. It’s concludes that has a good thermal and structural behavior, plus the characteristics of being economical and appropriate for selfconstruction, make feasible to implement as a massive scale.
  • 其他摘要:Wattle construction is a mixed technique used on walls and that belong to the frameworks family. It is constructed with a structural frame (wood or bamboo) filled in with a mixture of clay mud in a plastic state and vegetable fiber. In this paper thermal transmittance and soft shock resistance had been studied, thermal transmittance had been measured with wattle samples of 0.10 m thickness, and result in 2.64 W/m2K and with the addition of expanded polystyrene sheet of 5 mm thicknees inside the panel, the transmittance was 2.02 W/m2K. These values are batter than a brick wall of 0.20 m thick with a finish plaster on both sides of the wall, whose value is 4.13 W/m2K. For impact resistance, panels were constructed and tested to soft shock, on 1:1 scale. The permanent deformation in all cases was less than 3.6 mm required by the current standard. This implies that there was no appreciable deformations suffered enclosures providing security to a home. It’s concludes that has a good thermal and structural behavior, plus the characteristics of being economical and appropriate for selfconstruction, make feasible to implement as a massive scale.
  • 关键词:Quincha; transmitancia térmica; impacto en muros
  • 其他关键词:Wattle; thermal transmittance; impact on walls
国家哲学社会科学文献中心版权所有