摘要:SE REPORTAN MEDIDAS DE LAS CONSTANTES DE FOTOLISIS DEL NO2 A NO Y O(3P) COMO FRECUENCIAS DE FOTOLISIS J(NO2) PARA LA CIUDAD DE MÉXICO. ESTAS FRECUENCIAS SE MIDIERON USANDO UN REACTOR, EN DONDE UNA CONCENTRACIÓN CONOCIDA DE NO2 SE FOTO DISOCIA PARA DIFERENTES TIEMPOS DE EXPOSICIÓN. LA RADIACIÓN UV SE MIDIÓ CON UN RADIÓMETRO EPPLEY. SE MUESTRA UNA COMPARACIÓN CON VALORES CALCULADOS USANDO UN MODELO DE TRANSFERENCIA DE RADIACIÓN Y LA FORMULA DE MADRONICH.
其他摘要:Direct measurements of the rate of NO2 photolysis to NO and 0(3P) are reported as photolysis frequencies J(NO2) for Mexico City. These frequencies were measured using a flow reactor, where a known concentration of NO2 was photolysed for different experimental exposure times. UV radiation was measured with an Eppley UV radiometer. Comparisons with calculated values using a radiation transfer model, and Madronich's formula are shown.