首页    期刊浏览 2025年05月01日 星期四
登录注册

文章基本信息

  • 标题:Efetividade de programa de controle de qualidade em mamografia para o Sistema Único de Saúde
  • 本地全文:下载
  • 作者:Rosangela da Silveira Corrêa ; Ruffo Freitas-Junior ; João Emílio Peixoto
  • 期刊名称:Revista de Saúde Pública
  • 印刷版ISSN:0034-8910
  • 出版年度:2012
  • 卷号:46
  • 期号:5
  • 页码:769-776
  • 语种:Portuguese
  • 出版社:Universidade de São Paulo
  • 摘要:OBJETIVO: Avaliar a efetividade de um programa de controle de qualidade de imagem nos serviços de mamografi a da rede do Sistema Único de Saúde. MÉTODOS: Estudo prospectivo com análise temporal do tipo “antes e depois” de uma ação de vigilância em saúde. Participaram do estudo 35 serviços que tinham mamógrafos em operação e realizavam exames regularmente em Goiás entre 2007 e 2009. Foram avaliados os serviços, por testes de desempenho de mamógrafos, processadoras e demais materiais em três visitas técnicas, a qualidade da imagem e a dose de entrada no simulador radiográfi co de mama. Cada serviço recebeu uma pontuação correspondente ao percentual dos testes em conformidade com os padrões. RESULTADOS: Os percentuais médios de conformidade dos serviços foram de 64,1% (+ - 13,3%) na primeira visita, 68,4% (+ -15,9%) na segunda e 77,1% (+ -13,3%) na terceira (p < 0,001). As principais melhorias foram decorrentes dos ajustes da força de compressão da mama, do controle automático de exposição e do alinhamento da bandeja de compressão. As doses medidas estavam dentro da faixa de conformidade em 80% dos serviços avaliados. CONCLUSÕES: A implantação do programa nos serviços foi efetiva para a melhoria dos parâmetros de operação do mamógrafo, embora 40% dos serviços não tenham alcançado o nível aceitável de 70%. Este resultado indica a necessidade de haver continuidade na vigilância em saúde.
  • 其他摘要:OBJECTIVE: To assess the effectiveness of a quality control program in mammography services of the Brazilian National Health System (SUS). METHODS: A prospective study using temporal analysis of a health surveillance action was conducted. A total of 35 service providers that had mammography equipment in operation and regularly performed exams between 2007 and 2009 in the state of Goiás, Central-Western Brazil, participated in this study. Services were assessed during three site visits by performance testing of mammography equipment, fi lm processors, and other materials, and image quality and entrance surface dose in a phantom were also assessed. Each service was scored according to the percentage of tests that conformed to standards. RESULTS: The mean percentage for compliance among the participating service providers were 64.1% (+ -13.3%) in the fi rst visit, 68.4% (+ - 15.9%) in the second, and 77.1% (+ -13.3%) in the third (p < 0.001). The main improvements resulted from adjustments to the breast compression force, the automatic exposure control system, and the alignment of the compression paddle. The doses measured were within the conformity range in 80% of the services assessed. CONCLUSIONS: The implementation of this program in the mammography services was effective at improving the operational parameters of the mammography machines, although 40% of the services did not reach the acceptable level of 70%. This result indicates the need to continue this health surveillance action.
  • 关键词:Mamografia; normas; Efetividade; Avaliação de Eficácia-Efetividade de Intervenções;Garantia da Qualidade dos Cuidados de Saúde; Sistema Único de Saúde; eoplasias da Mama; diagnóstico.
  • 其他关键词:Mammography; standards; Effectiveness; Evaluation of the Efficacy-Effectiveness of Interventions; Quality Assurance; Health Care; Brazilian Public Health System; Breast Neoplasms; diagnosis.
国家哲学社会科学文献中心版权所有