首页    期刊浏览 2024年11月08日 星期五
登录注册

文章基本信息

  • 标题:Evaluation of Auditory Evoked Potential and Bispectral Index in Patient-Controlled Sedation with Propofol
  • 本地全文:下载
  • 作者:Kim, Dong Hee ; Kim, Ji Wook ; Lee, Hae Won
  • 期刊名称:Korean Journal of Anesthesiology
  • 印刷版ISSN:2005-6419
  • 出版年度:2004
  • 卷号:46
  • 期号:5
  • 页码:541-547
  • DOI:10.4097/kjae.2004.46.5.541
  • 语种:English
  • 出版社:The Korean Society of Anesthesiologists,
  • 摘要:Background

    The auditory evoked potential (AEP) index and bispectral (BIS) index have been proposed as methods to measure the depth of sedation. A prospective study was designed to assess the performance of both these methods for measuring the depth of sedation induced by propofol patient-controlled sedation (PCS) under spinal anesthesia.

    Methods

    Forty ASA I and II adult patients under spinal anesthesia using 0.5% hyperbaric bupivacaine were studied. Group 1 (10 mg bolus, 30 mg loading) and Group 2 (20 mg bolus, 60 mg loading) received propofol and maintained PCS with 1min lockout interval and 100 mg/hr continuous infusion. AEP, BIS and Observer's assessment of alertness/sedation (OAA/S) scale were monitored during the operation.

    Results

    AEP and BIS decreased and increased following the changes on the patient's OAA/S scores and correlated with sedation significantly. There were no significant difference in mean AEP index (group 1; 13.4 ± 8.4, group 2; 8.9 ± 6.2), BIS index (group 1; 76.2 ± 9.7, group 2; 71.2 ± 9.8), and OAA/S scale (group 1; 3.8 ± 1.3, group 2; 3.2 ± 1.5) between the groups. Incidence of perioperative respiratory depression was significantly higher in group 2 (25%) than group 1 (5%), and incidence of involuntary movement was significantly higher in group 1 (20%) than group 2 (5%) (P < 0.05).

    Conclusions

    Both AEP and BIS correlated well with the depth of sedation induced by propofol PCS under spinal anesthesia. AEP seems to be more valuable in measuring the change between consciousness and unconsciousness, and BIS seems to be more effective in measuring the depth of sedation.

  • 关键词:auditory evoked potential (AEP); bispectral (BIS) index; propofol; patient-controlled sedation (PCS); spinal anesthesia
国家哲学社会科学文献中心版权所有