期刊名称:International Journal of Innovative Research in Science, Engineering and Technology
印刷版ISSN:2347-6710
电子版ISSN:2319-8753
出版年度:2015
卷号:4
期号:2
页码:450
DOI:10.15680/IJIRSET.2015.0402032
出版社:S&S Publications
摘要:In this paper, transient behaviours of the Doubly Fed Induction Generator using Simulink model isdemonstrated. A mathematical model based on d-q transformation i.e. stator phase currents, rotor currents, stator fluxlinkages,rotor flux linkages ,instantaneous power electromagnetic torque is also presented. In this paper 9 MW windfarm consisting of six 1.5 MW wind turbines connected to a 25 kV distribution system exports power to a 120 kV gridthrough a 30 km, 25 kV feeder has been considered. It is concluded in proposed Simulink model, when 3- phasesymmetrical fault occur at the grid during t = 0.04s to t = 0.06s, the sudden voltage reduction gives to a lower powerinjection into the network both active power & reactive power are almost abrupt. This behaviour also depends on therotor side converter during the fault.