期刊名称:International Journal of Innovative Research in Science, Engineering and Technology
印刷版ISSN:2347-6710
电子版ISSN:2319-8753
出版年度:2015
卷号:4
期号:7
页码:5931
DOI:10.15680/IJIRSET.2015.0407073
出版社:S&S Publications
摘要:The study characterizes the exposure of a typical gaseous co-pollutant like carbon dioxide, carbonmonoxide, on students with in college campus, under various microenvironments in Bangalore city. By the aid ofStandalone Air Quality Monitor, monitoring was done to determine the concentration of the gases such as CO2, CO.Furthermore, health analysis of the monitoring survey area and comparison of the result with prescribed standardsavailable were also carried out to determine the various ill-health effects caused by it. The results showed during thereal time monitoring period, the measurements carried out in different microenvironments were quite stable and hardlyany major variation was found, except those at the college canteen and chemistry laboratory. The peak values of CO2determined in canteen (kitchen) and computer laboratory (without A.C) were reported higher than found in any othermicroenvironment. The concentration of CO2 and CO in college canteen (kitchen) were found to be exceeding thestandards by almost twofold. Health survey conducted revealed problems like headache, dizziness, respiratorydiscomfort, confusion etc. due to elevated gaseous concentration in various microenvironments can prove to be apromising human health risk assessment measure based on the relative time spent in a particular environment.
关键词:Indoor air quality; Indoor Environment; real time monitoring; Occupancy; Productivity; College;Building