标题:“UTILITY OF STROKE VOLUME VARIATION AS A PREDICTOR OF FLUID RESPONSIVENESS USING THIRD GENERATION VIGILEO DEVICE IN PATIENTS UNDERGOING BRAIN SURGERY”
期刊名称:IMPACT : International Journal of Research in Applied, Natural and Social Sciences
印刷版ISSN:2347-4580
电子版ISSN:2321-8851
出版年度:2014
卷号:2
期号:4
页码:185-192
语种:English
出版社:IMPACT Journals
摘要:Background Assessment of Stroke volume variation (SVV) using minimally invasive devices in mechanically ventilated patients has been in use for several years to guide fluid administration. This study was designed to assess the utility of SVV derived from arterial pulse contour analysis, using FloTrac/Vigileo system to predict fluid status in patients scheduled for brain surgery. Method We studied 60 adult patients undergoing brain surgery. After a 5min period of stable hemodynamic parameters post-intubation, each patient received successive volume loading steps(VLS), of 200ml lactated Ringer's solution (LR), until the increase in SV(stroke volume) was