摘要:Phenol is one of the serious pollutants from the chemical and petrochemical industries. This pollutant due to its convoluted structure is resistant to biodegradation. One of the methods that are useful to remove this pollutant is advanced oxidation (AOP). A laboratory scale study was done on a synthetic wastewater containing phenol. All experiments were done in batch conditions and effect of variables pH, amount of hydrogen peroxide, iron dosage, contact time and an initial concentration on the phenol removal were tested. The remaining phenol concentration was evaluated using the DR-5000 device. In order to effect of these parameters, the experiment was performance at pH 2 to 6, 5 to 45 ml/ml of peroxide, and time of 5 to 60 minutes with 2 to 15 g/ml iron (Fe˚). The optimum pH, the ratio of hydrogen, Fe˚and time were 3, 15 ml, 8g and 5 minutes respectively. Chemical oxygen demand (COD) index was chosen as the parameter for evaluation in this study. Result showed that mineralization of phenol was not complete. The COD removal efficiency was obtained 71%. According to the results of this study, Fenton-like process can be used for conversion organic resistant compounds to other compounds with lower toxicity