首页    期刊浏览 2024年11月28日 星期四
登录注册

文章基本信息

  • 标题:Posterior Plating in Distal Fibular Fracture
  • 本地全文:下载
  • 作者:Choi, Choong-Hyeok ; Cho, Young-A ; Kim, Jae-Hoon
  • 期刊名称:Journal of the Korean Fracture Society
  • 印刷版ISSN:1225-1682
  • 出版年度:2007
  • 卷号:20
  • 期号:2
  • 页码:161-165
  • DOI:10.12671/jkfs.2007.20.2.161
  • 语种:Korean
  • 出版社:The Korean Fracture Society
  • 摘要:Purpose

    To report the technical experience of posterior plating for the distal fibular fracture.

    Materials and Methods

    20 Weber type-B fibular fractures were included in this study, which were treated with the posterior plating. 1/3 semitubular plate was used and orientation of all screws were intended to be perpendicular to the plate as possible. Fixation stability and maintenance of reduction after plating was assessed manually in the operating field. Clinical results were evaluated at least 1 year after operation, using American Orthopaedic Foot and Ankle Society (AFOAS) Ankle-Hindfoot score.

    Results

    5 cases were firmly stabilized without using any lag screw or fixation of distal fragment. For improving stability or achieving proper reduction, a lag screw was placed posteroanteriorly through the plate in 14 cases. Anteroposterior interfragmentary fixation in 1 case before plating, and contouring of the plate in 3 cases were needed in cases of which the posterior plating impeded reduction of distal fibular fracture. In all cases, fracture was stabilized without fixation through the most distal hole. There were no major postoperative complications. AFOAS score was 95.5±5.2.

    Conclusion

    The posterior plating technique for distal fibular fracture is regarded as a recommendable option. Additional fixation with interfragmentary screw or contouring of the plate, however, would be needed in some cases to achieve anatomical reduction or sufficient stability.

  • 关键词:Distal fibular fracture; Posterior plate
国家哲学社会科学文献中心版权所有