首页    期刊浏览 2024年10月06日 星期日
登录注册

文章基本信息

  • 标题:A Comparision of Plate Fixation with Intramedullary Nailing in Treatments of Humeral Shaft Fracture
  • 本地全文:下载
  • 作者:Lee, Duk Yong ; Shim, Jae Ik ; Kim, Taik Seon
  • 期刊名称:Journal of the Korean Fracture Society
  • 印刷版ISSN:1225-1682
  • 出版年度:1998
  • 卷号:11
  • 期号:3
  • 页码:696-702
  • DOI:10.12671/jksf.1998.11.3.696
  • 语种:Korean
  • 出版社:The Korean Fracture Society
  • 摘要:

    Authors report 42 cases of humeral shaft fractures, which were treated with plate fixation in 19 cases and intramedullary(IM) nailing in 23 cases, from January 1992 to December 1996. The average time of operation in plate fixation was 100 minutes and that in Im nailing was 65 minutes. The nonunion in plate fixation was 2(10.5%)cases and that in IM nailing was 4(17.4%)cases. Other complications of plate fixation were 2 cases of wound infection and 2 cases of radial nerve palsy. Those of IM nailing were 1 case of limited motion of the shoulder and 1 case of wound infection. After reviewing above reslts, we concluded that there were no marked difference between the two operative method in bone union of humeral shaft fracture cxcept diversity of complication.

  • 关键词:Humerus; shaft fracture; Intramedullary nail; Plate fixation
国家哲学社会科学文献中心版权所有