摘要:Finite set model predictive control (FS-MPC) has become a promising control technology in power converter, because of the advantages of good dynamic response and accurate current tracking capability. In real-time control process, the conventional FS-MPC strategy requires more time for prediction and optimization. As a result, there will be a certain delay between sampling and output. In order to reduce the amount of calculation and overcome the adverse effect of the delay on the system performance, this paper presents a simplified FS-MPC method. Firstly, adjacent levels method is used to reduce the amount of the calculation, and then two-step FS-MPC is adopted to compensate the calculation delay. The control strategy is validated by the simulation and experimental results of a grid-connected cascaded H-bridge converter.