首页    期刊浏览 2024年10月06日 星期日
登录注册

文章基本信息

  • 标题:Prevention of Fracture During Removal of ILMN in Tibia Fracture
  • 本地全文:下载
  • 作者:Kim, Bu Hwan ; Choi, Myoung Hee ; Yi, Sang Hun
  • 期刊名称:Journal of the Korean Fracture Society
  • 印刷版ISSN:1225-1682
  • 出版年度:2001
  • 卷号:14
  • 期号:4
  • 页码:628-631
  • DOI:10.12671/jksf.2001.14.4.628
  • 语种:Korean
  • 出版社:The Korean Fracture Society
  • 摘要:Purpose

    Sometimes we experience refracture of tibia during removal of ILMN after complete union of fracture. We evaluated surgical technique in order to know how we can avoid the fracture of posterior cortex of tibia during removal of ILMN.

    Materials and Methods

    From Jan. 1993 to Dec. 1999, we removed 86 cases of ILMN used for tibia fracture. Among them, 40 cases of Ace titanium ILMN were removed. We compared the fracture rate of tibia during removal of Ace titanium ILMN.

    Results

    The refracture rate during removal of Ace titanium ILMN was 17.2% (5/29cases) previously, but after careful "slow and steady" removal of nail, the refracture rate was reduced to 0%(0/11 cases, P<0.05).

    Conclusion

    Take some cares during removal of ILMN is important to reduce the fracture rate of tibia during removal of Ace titanium ILMN.

  • 关键词:Tibia; refracture; Removal of ILMN
国家哲学社会科学文献中心版权所有