首页    期刊浏览 2024年11月27日 星期三
登录注册

文章基本信息

  • 标题:Treatment of Comminuted Fracture of the Distal Humerus by New Y-Anatomical Plate
  • 本地全文:下载
  • 作者:Chun, Churl Hong ; Kim, Sang Soe ; Rowe, Sung Man
  • 期刊名称:Journal of the Korean Fracture Society
  • 印刷版ISSN:1225-1682
  • 出版年度:1996
  • 卷号:9
  • 期号:4
  • 页码:1076-1084
  • DOI:10.12671/jksf.1996.9.4.1076
  • 语种:Korean
  • 出版社:The Korean Fracture Society
  • 摘要:Objectives

    The characteristics of comminuted fractures of the distal end of the humerus in adult are severe comminution of bony fragments, loss of bony continuity and displaced fragments by muscle action. The ideal treatment is to reestabilish a normal elbow-that is to reestablish the articular congruity. the alignment and early motion as soon as pessible. But no matter what treatment is used perfect results are seldom obtained. The purpose of this study is to analyze the clinical results of the new Y-Anatomical plate, which has well adaptable and more malleable characteristics for the fracture of the distal humerus.

    Materials and nletheds

    The fracture types of the distal humerus were 5 supracondylar and 12 intercondylar, which were classified according to the Riseborugh & Radin classification 4 type II, 2 type III and 6 type IV. The patients who have been treated by new Y-Anatomical plate from September 3992 to January 1995.

    Results

    Fourteen of the 17 cases(81.2%) were considered acceptable results for a mean follow-up 26 months study according to the functional motion of the elbow by Cassebaum and criteriae by Jupiter J.B.etc. The patient who did exercise the elbow joint within two weeks from post-operation, gathered better results than other patients who did it after four weeks from post-operation. Complications are nonunion, ankylosing elbow and metal failure.

    Conclusion

    In the study reported here, new Y-Anatomical plate was sufficiently obtained the anatomical reduction with stable fixation, so it would allow early motion of the elbow joint to be possible and decrease the complication compared to Tri-radiate plates. Also the most important indicator of end result was the starting time of physiothmpy.

  • 关键词:Humerus; distal comminuted fracture; New Y-anatomical plate
国家哲学社会科学文献中心版权所有