期刊名称:ISPRS Annals of the Photogrammetry, Remote Sensing and Spatial Information Sciences
印刷版ISSN:2194-9042
电子版ISSN:2194-9050
出版年度:2006
卷号:XXXVI Part 5
出版社:Copernicus Publications
摘要:In this paper, we describe an automatic approach for a terrestrial line scanner calibration. The system is calibrated with prior knowledge of the exterior orientation of the camera in an unknown coordinate system. This data is acquired by tracking the moving sensor platform with an infrared camera tracking system (ARTtrack2) along a calibration scene. The calibration of a line scanner includes the determination of the transformation parameters to the known control point coordinate system (translation and rotation) and three parameters of the one-dimensional distortion model (simplified B ROWN ) for the sensor array. The focal length of the camera is assumed to be known. After a first rectification of the data with the tracking observations, photogrammetric targets are automatically detected and decoded. Finally, the distortion parameters of the camera and the transformation between world- and tracking coordinates are iteratively estimated
关键词:line scanner; calibration; position tracking; coded targets; convincedness; segmentation