摘要:In hilly areas buildings are built on sloping grounds. When the hilly areas come under the seismiczones, these buildings are highly vulnerable to earthquakes. This is due to the fact that the columns in the ground storeyare of different heights in such a way that column in one end is a short column and column in other end is a longcolumn. Along with this if the building has an open ground storey, the seismic vulnerability is further increases. Thispaper deals with the comparison of seismic performance of soft storey building on sloping grounds and soft storeybuilding retrofitted with shear wall. The aim of the paper is to check if the seismic performance of the structure isimproved when it is retrofitted with shear wall.