首页    期刊浏览 2024年12月03日 星期二
登录注册

文章基本信息

  • 标题:Marginal Water Treatment by Combination of Two Stages of Stepped Cascade Weir and Spray Aerator
  • 本地全文:下载
  • 作者:Dheyaa Wajid Abbood ; Ayad Sleibi Mustafa ; Eitizaz Awad Jasim
  • 期刊名称:Civil and Environmental Research
  • 印刷版ISSN:2225-0514
  • 电子版ISSN:2225-0514
  • 出版年度:2015
  • 卷号:7
  • 期号:11
  • 页码:22-29
  • 语种:English
  • 出版社:The International Institute for Science, Technology and Education (IISTE)
  • 摘要:A combination of stepped cascade weir with spray aerator systems is one of the available ecological treatments to reduce the concentration of pollutants in marginal water and to solve the problem of the water shortage for irrigation and industrial uses in Iraq. An experimental treatment system for marginal water has been constructed and installed at Al- Mustansiriya University, College of Engineering during the period from August 2013 to July 2014. The performance of the treatment schemes has been evaluated by monitoring the quality of marginal water and effluent for some parameters such as pH, Cl - , BOD 5 , COD, Fe +2 , and Mn +2 . Results indicate that the removal efficiencies for COD and BOD 5 is ranged from (43% to 51%), and (44%-52%), that the removal efficiency of ions concentrations such as Fe +2 , Mn +2 , are (30 %-48%) %, and (33% -48%), respectively, while for Cations such as Cl-, the removal efficiency is (31%-42%).
  • 其他摘要:A combination of stepped cascade weir with spray aerator systems is one of the available ecological treatments to reduce the concentration of pollutants in marginal water and to solve the problem of the water shortage for irrigation and industrial uses in Iraq. An experimental treatment system for marginal water has been constructed and installed at Al- Mustansiriya University, College of Engineering during the period from August 2013 to July 2014. The performance of the treatment schemes has been evaluated by monitoring the quality of marginal water and effluent for some parameters such as pH, Cl - , BOD 5 , COD, Fe +2 , and Mn +2 . Results indicate that the removal efficiencies for COD and BOD 5 is ranged from (43% to 51%), and (44%-52%), that the removal efficiency of ions concentrations such as Fe +2 , Mn +2 , are (30 %-48%) %, and (33% -48%), respectively, while for Cations such as Cl-, the removal efficiency is (31%-42%). Keywords: Marginal water, spray aerator, bio-treatment, stepped cascade weir.
  • 关键词:Marginal water; spray aerator; bio-treatment; stepped cascade weir.