  • 标题:Strengthening of Continuous SCC Hollow Beams under Shear Stresses Using Warped CFRP Strips
  • 本地全文:下载
  • 作者:Ali Hameed Aziz ; Ashraf A. Alfeehan ; Fawaz Adel Hussein
  • 期刊名称:Civil and Environmental Research
  • 印刷版ISSN:2225-0514
  • 电子版ISSN:2225-0514
  • 出版年度:2016
  • 卷号:8
  • 期号:3
  • 页码:105-116
  • 语种:English
  • 出版社:The International Institute for Science, Technology and Education (IISTE)
  • 摘要:The present paper is deal with shear strength evaluation of continuous self-compacting concrete hollow beams containing internal concrete ribs and externally strengthening by carbon fiber strips (CFRP). Six full-scale beam specimens and series of control specimens were tested. The adopted variables in this study are the number of internal concrete ribs and external U-shape CFRP strips at (45º). Experimental results show that the shear failure was the dominant failure for all tested beams. The cracking and ultimate load are reduced by about (19.6-30.6%) for the hollow beams specimens contains five and three ribs respectively compared with the reference beam. The ultimate load was increased for about (50.7%) for five internal ribs hollow beams strengthened by CFRP strips in compared with the same beams but without strengthening. While, the ultimate load was increased for about (33.46%), for beam specimen who has three internal ribs and strengthened by CFRP, in comparison with the same beams but without strengthening.
  • 其他摘要:The present paper is deal with shear strength evaluation of continuous self-compacting concrete hollow beams containing internal concrete ribs and externally strengthening by carbon fiber strips (CFRP). Six full-scale beam specimens and series of control specimens were tested. The adopted variables in this study are the number of internal concrete ribs and external U-shape CFRP strips at (45º). Experimental results show that the shear failure was the dominant failure for all tested beams. The cracking and ultimate load are reduced by about (19.6-30.6%) for the hollow beams specimens contains five and three ribs respectively compared with the reference beam. The ultimate load was increased for about (50.7%) for five internal ribs hollow beams strengthened by CFRP strips in compared with the same beams but without strengthening.  While, the ultimate load was increased for about (33.46%), for beam specimen who has three internal ribs and strengthened by CFRP, in comparison with the same beams but without strengthening. Keywords: CFRP Strips, Shear, Continuous Beam, Self-Compacting Concrete, Hollow, Ribs
  • 关键词:CFRP Strips; Shear; Continuous Beam; Self-Compacting Concrete; Hollow; Ribs