摘要:This paper presents the results of an economic analysis of a triple-pressure combined cycle power plant with the steam reheater (3PR). The economic analysis was performed for two variants of the block - with and without the integration of the system with the installation of CO 2 capture and compression. The structures of the triple-pressure combined cycle power plant with the steam reheater and CO 2 capture and compression installation (CCS) was presented. The characteristic values of systems and the economic assumptions were summarized. An analysis of a break-even point (BEP), which was the minimum selling price for electricity, was performed. A sensitivity analysis of individual components to a break-even price of electricity and the impact of degradation of the efficiency and the power characteristics of the combined cycle power plant was conducted.