首页    期刊浏览 2024年09月21日 星期六
登录注册

文章基本信息

  • 标题:Operation of a conceptual A-USC power unit integrated with CO2 capture installation at part load
  • 本地全文:下载
  • 作者:Katarzyna Stępczyńska-Drygas ; Krzysztof Bochon ; Sławomir Dykas
  • 期刊名称:Bulletin of the Institute of Heat Engineering
  • 印刷版ISSN:2083-4187
  • 出版年度:2013
  • 卷号:93
  • 期号:5
  • 页码:383-393
  • 语种:English
  • 出版社:Warsaw University of Technology
  • 摘要:Nowadays, the main aim of the development of coal-fired power industry concentrates on improving the efficiency of electricity generation and on reducing the CO 2 emission. Modern power systems require from the power units ability to flexible work at part loads with high efficiency. The paper presents the conceptual 900 MWcoal-fired power unit. Unit operates with advanced ultra-supercritical (A-USC) steam parameters 35MPa/700ºC and net efficiency of 49%. Improvement of the efficiency results in significant reduction of CO 2 emission. Further reduction of emission requires integration of coal-fired power plants with CO 2 capture installation. Newly built power plant offers a possibility of fully optimized integration to reduce the efficiency loss, which is related with post-combustion capture process. The CO 2 capture by wet chemical absorption MEA can be characterized with three indicators: the demand for heat, electric power to drive auxiliary equipment and cooling. In order to calculate these indicators the capture process was modeled in Aspen Plus. Calculated indicators for nominal and part load operation were used to model integrated power unit in Ebsilon Professional 10.0. The characteristics of operation of power unit integrated with CO 2 capture installation were determined.
国家哲学社会科学文献中心版权所有