The influence of the number of Teflon-coated layers over the vibrations and noises to gear units with wheel cylindrical gears.
Caramidaru, Virgil Dan ; Vela, Ion ; Tufoi, Marius 等
Abstract: This article represents a summary of the documentation
and of theoretical and experimental research activity carried out by the
authors in the field of the vibrations and noises produced by the
transmission with Teflon-coated cylindrical gears. The experimental
researches were performed on a test stand existing within the University
"Eftimie Murgu", Resita, on whose gear a one, two and three
layers of fluoro-polymerised Xylan 1052 were filled.
The purpose of the study is to analyse the influence of the number
of the Teflon coated layers on the vibrations and noises.
Key words: vibration, noise, fluoro-polymerised, Xylan 1052, torque
loadings
1. INTRODUCTION
These coating technologies give to the metal surface superior
tribological properties under poor lubrication, or dry friction, by
applying fluoro-polymer composite materials. Another advantage of these
technologies is that they can be applied on metal support new or if
worn, within the fluoropolymer layer thickness can be achieved, there
are also reconditioning technology, saving the metal support, which
means an important economy of material and workmanship. These
technologies are environmental technologies.
Fluoro-polymer material used to improve the tribological behavior
of the gear teeth and for the noise reduction is the Xylan 1052
dispersion--produced by Whitford Plastics Ltd, the UK, which is applied
only on the flanks of teeth gears in one, two and three layers, the
thickness of a layer being, after appropriate heat treatment, of 12 to
20 microns. The fluorpolymer layer obtained after appropriate heat
treatment resists to a range of operating temperatures between 195 /
285[degrees]C and can operate at extreme pressure, which can exceed
those of 3500 kgf/cm2.
2. PROBLEM FORMULATION
The reducer is a horizontal-stage, with a step and coaxial input
and output shaft.
For testing at variable speeds, the driving was done from a DC
motor and as loading system, which makes possible the variation of
torque transmitted by gear, was chosen the involvement of oil pumps with
a geometrical volume of 405 [cm.sup.3] / rot which can provide a maximum
pressure of 25 bar. The check of the power transmitted, respectively of
the torque, to the input shaft and output shaft of the gearbox, was
using T-10 FS torsiometrical flanges.
For isolation gear in terms of possible vibration from the driving
car (electric motor) and driven machine (pump), were chosen couplings
with rubber bands on the input shaft, respectively with rubber bands on
the output shaft. These couplings have the advantage of allowing quick
disconnection and requires no alignment, respectively rigorous
centering. The measuring of the vibration and noise were made through
PULSE platform 11, existing in the equipment of Eftimie Murgu University
from Resita, with related software (FFT analyzer (Fast Fourier
Transformation) type 7700) capable of receiving signals from sensors on
four channels, produced by The Bruell & Kjaer.
The first three channels were used to type piezoelectric accelerometers 4524 B (triaxial aceelerometers with three independent
outputs for measurements along three orthogonal directions) and the
fourth channel was used for piezo frequently microphone with frequency
between 8 Hz and 16 kHz especially designed for accurate and reliable
measurements of the sounds. In Figure 1 transducers of vibration and
noise are placed.
[FIGURE 1 OMITTED]
3. EXPERIMENTAL TESTS
Experimental tests were made on a pair of gears (pinion + gear
wheel), the angle of the teeth 11[degrees] and with teeth processed by
milling and on which (teeth), one, two and three layers of Fluor-polymer
Xylan 1052 were made in collaboration with Technicoat ROMANIA SRL Campina. Data collection was made at the same six-speed motor drive:
[n.sub.1] = 1.000, 1.100, 1.200, 1.300, 1.400 and 1.500 [rpm]. No
vibration measurements were made at engine speeds below 1.000 [rpm],
because dynamic effects become apparent at increasing speed at low revs
not being able to draw relevant conclusions, respectively, for pump
gear, used as a brake not work optimally in the speeds under 390 r / min
([n.sub.2] = [n.sub.1] / i = 1000 / 2.59 = 395.3 [r / min]). At each
speed in part, vibration measurements were made at the same eight steps
of torque loadings: Mt = 16, 19, 22, 26, 29.5, 32.5, 35.5, 38.5 [Nm].
Extreme values were resulted from the specific conditions of the made
test stand. Figure 2 shows the mounting position of the pinion and gear
wheel. Teeth are covered with Xylan 1052 dispersion of dark green colour
as shown in Figure 2.
[FIGURE 2 OMITTED]
4. EXPERIMENTAL RESEARCH
Because we wanted to study only the vibration produced by gears,
the analyze FFT (Fast Fourier Transformation) was used, recording peaks
(amplitudes) of the accelerations and velocities measured at the
frequency of engagement, respectively its harmonics. The values of these
frequencies are shown in Table 1.
In the graph in Figure 3 there are presented in comparison: the
teflon-coated teeth with one, two or three layers of fluoropolymer
material Xylan 1052, the maximum amplitude variation of acceleration on
two axex (X and Y) of the bearing A, measured at maximum speed (n =
1.500 rpm) of the driven motor, depending on torque loadings.
[FIGURE 3 OMITTED]
According to the graph in Figure 3 from the teeth covered with one
layer of Xylan 1052 there is registered a decrease of:
* 30% for the teeth covered with two layers Xylan 1052;
* 60.98% for the teeth covered with three layers Xylan 1052;
In the graph in Figure 4 there are presented in comparison: the
teflon-coated teeth with one, two or three layers of fluoropolymer
material Xylan 1052, the changes in noise levels measured at maximum
speed (n = 1.500 rpm) of the driven motor, depending on torque loadings.
[FIGURE 4 OMITTED]
According to the graph in Figure 4 from the teeth covered with one
layer of Xylan 1052 there is registered a decrease of:
* 1.31% for the teeth covered with two layers Xylan 1052;
* 2.65% for the teeth covered with three layers Xylan 1052;
5. CONCLUSIONS
Appying a multi-layer film dispersion type Xylan 1052, on the
sidewall surfaces of teeth, there were obtained decreases of maximum
amplitude of vibration and noise. Overall, it was observed that in most
cases, there are larger differences between one and two layers than two
to three coats applied. However the film with three layers is damper
than a film with two layers, but the difference is not visible in all
cases investigated. This leads us to conclude that if there is no need
to get the best damping of vibrations and noises it is better not to do
additional work and to choose a film with two layers Xylan 1052.
6. ACKNOWLEDGEMENTS
Special thanks to Mr. Zoltan Korka from "Reductoare Resita
SA" for the design and execution of the test stand. We also thank
SC Technicoat ROMANIA SRL Campina for filling the tooth flanks of the
gears with one, two and three layers of fluoropolymer Xylan 1052.
7. REFERENCES
Bratu, M.; Ropota, I.; Vasile, O.; Dumitrescu, O.; Munteanu, M.
(2011). Reserch on the absorbing properties of same new types of
composite materials, Romanian Journal of Materials, vol. 41 (2), ISSN 1583-3186, pp. 147-154
Korka, Z. I. (2009). Cercetari privind reducerea vibratiilor in
functionarea reductoarelor cu roti dintate cilindrice, Teza de Doctorat,
Universitatea "Eftimie Murgu" Resita, Facultatea de Inginerie
Korka, Z.; Vela, I. (2008). Design and Execution of a Test Rig for
Studying the Vibrations of a Gearbox, Analele Universitatii
"Eftimie Murgu" Resita, Fascicola Inginerie, ISSN 1453-7397,
Nr.1, pp. 134-140
Agemi, M. F.; Ognjanovic, M. (2004). Gear Vibration in
Supercritical Mesh-Frequency Range, FME Transactions, vol. 32, nr. 2,
pp. 87-94
Nguyen, V. K.; Thai, M. C.; Nguyen, P. D. (2004). Modelling
Parametric Vibration of Gear-Pair Systems as a Tool for Aiding Gear
Fault Diagnosis, Technische Mechanik, Band 24, Heft 3-4, pp. 198-205
Tab. 1. Frequency of engagement
Rotation
speed
[rpm] 1000 1100 1200 1300 1400 1500
f [Hz] 83.33 311.67 40.00 68.33 96.67 25.00
2xf [Hz] 566.67 23.33 80.00 36.67 93.33 850.00
3xf [Hz] 850.00 935.00 1020.00 1105.00 1190.00 1275.00