Usage of heat obtained by cooling of shaft furnaces of "Trepca" corporation with water steam.
Terziqi, Avni ; Rizaj, Musa ; Kamberaj, Naim 等
Abstract: The lead agglomerate's melting process is
accompanied with numerous technical, technological and economic
difficulties, including the cooling process of the furnace as well. This
paper has been analyzing the possibility of using the heat obtained from
the shaft furnace by its cooling with water steam. In order to achieve
these aims, alongside with the corresponding scheme, in the paper have
been compiled appropriate systems of equations related to mass and heat
balances, needed to calculate thermal and technical parameters of the
characteristic system's points. The corresponding results have been
discussed as well. Effects of this system in increasing of the heat
usage coefficient are of interest for the purpose of technological
process economizing of shaft furnaces within "Trepca"
metallurgical corporation.
Key words: heat usage, furnace, cooling, water.
1. INTRODUCTION
Cooling of Trepca water-jacket furnace till now was made according
to half-closed recirculation process, without using heat released from
the furnace. In this process grade of water heating is low, and this
heat is awkward for use (Agolli 1985). With development and construction
perfection of modern metallurgic furnace, increases also demand for use
of heat, which is ejected during cooling process. Cooling manner with
evaporation distinctly fulfil needs of using heat from melting process
in furnace. At evaporation cooling, ejected heat, is in contents of
steam and has higher temperature and can be used for other destinations.
For usage of this heat of cooling with evaporation, it can be done
incubation for developing of burning process in furnace and incubation
of sanitary water for needs of lead metallurgy. Decision on utilization
of secondary resources behaves depending from economic effects and
environmental protection taking in regard to not destroy basement for
technologic process.
2. THERMAL SCHEME OF PROPOSED COOLING SYSTEM
In system for cooling elements of shaft furnace, is proposed to
apply cooling with steam (PFA--FV). In this process heating is taken
from cooler rows of furnace roper where gained water steam is. As we can
see from Fig. 1, circular heat water (UNC) gets in cooling process with
steam of shaft furnace (PFA-FV), takes one quota of heat and gradually
come in circular mixture steam-water (PCAU) where such as gets in
barrel-separator (CS). In barrel-separator (CS) is divided steam phase
from phase of fluid mixture. Saturated steam continues for further use,
whereas fluid phase in shape of circular hot water (UNC), again
recirculation and returns in cooling process with steam in shaft furnace
(1--PFAFV--2--CS--1).
Quantity of saturated steam that is divided in barrel-separator
(CS), goes in exchanger of heat KN1, where is taken a quantity of heat,
respectively saturated steam is condensed and again returns in
barrel-separator (CS--3 KN1--4--CS). In exchanger of heat KN1 circular
cold water gets in, warms up and gets out as circular hot water (UNC)
with help of circular pump (PC), (PC--5--KN1--6). Then circular hot
water partly goes in exchanger KN2, through line 7 and other part
through line 11 in exchanger KN3.
[FIGURE 1 OMITTED]
Exchanger of heat KN2 serves for heating o air, which is used for
developing of burning process in furnace. In KN2 is taken a quota of
circular hot water and as a circular cold water is returned again in
exchanger KN1 (7--KN2--8--5). In exchanger KN2 gets in cold water (AFPF)
warms up and as hot ait (ANPF) gets in furnace (9--KN2--10). Meanwhile
other of circular hot water gets in exchanger KN3 for heating of
sanitary water and returns in exchanger KN1 (11-12-5-6). Sanitary cold
water (UFS) which gets in exchanger KN3 warms up and ejects as sanitary
hot water (UNS), where goes for further use (13KN3-14). In
barrel-separator exists one safety-valve and the funnel for feed with
cold water chemically elaborated (UFKP)
3. EQUATION SYSTEM OF TERMIC BALANCE
Depending between parameters in characteristic points of cooling
system can be described with energy equation, with equation of consume
balance of energy bearers, equation of hydraulic balance and as well
with equation of enthalpy changes of energy bearers (Sacadura 1993).
Preliminarily should be appropriated values of some heat bearers
parameters and some other to be taken from calculation of encycled
cooling contour with evaporation: It's supposed that circular water
in KN1 and KN2, flow with regimen of known temperatures t5/t6 and t7/t8,
respectively UFC with temperature [t.sub.5] = [t.sub.8] = [t.sub.12] and
appropriated enthalpy [h.sub.5] = [h.sub.8] = [h.sub.12], whereas
circular (UNC) with known temperature [t.sub.6] = [t.sub.7] = [t.sub.11]
and with enthalpy [h.sub.6] = [h.sub.7] = [h.sub.11]. Quantity of
necessary air for heating (Ga)[5], that gets in exchanger KN2 is known
from material balance of furnace and has availability with known
temperature of surroundings [T.sub.9] with respective enthalpy
[h.sub.9], whereas we suppose that gets out with fixed temperature
[T.sub.10] with enthalpy [h.sub.10]. Meanwhile, from thermal and
hydraulic calculation of contour of evaporation process in furnace is
known that [G.sub.1] = [G.sub.2] = [G.sub.0], [G.sub.3] = [G.sub.4] =
DAF whereas [G.sub.9]=[G.sub.10]=[G.sub.a], where is: [G.sub.0]general
consume of water in contour; [x.sub.D] = [x.sub.SH2]--real capacity
content of steam in coolers and furnace funnels [D.sub.AF]--quantity of
steam that is generated in furnace coolers. Afterwards values of water
steam enthalpies: h', h'' and h are taken from standard
tables for thermo physic water attributes whereas
[h.sub.1]=[h.sub.4]=h', [h.sub.2]=h'+ [x.sub.D]h and
[h.sub.3]=h". Meanwhile differences of enthalpies are fixed from
equation system (Michael, J.; Howard, N. 2004.).
[DELTA][h.sub.1,2] = [X.sub.SH2] h (1)
[DELTA][h.sub.3,4] = h (2)
[DELTA][h.sub.5,6] = [h.sub.6]--[h.sub.5] (3)
[DELTA][h.sub.7,8] = [h.sub.7]--[h.sub.8] (4)
[DELTA][h.sub.9,10] = [h.sub.10]--[h.sub.9] (5)
[DELTA][h.sub.11,12] = [h.sub.12]--[h.sub.11] (6)
[DELTA][h.sub.13,14] = [h.sub.14]--[h.sub.13] (7)
Values of flow rate for characteristic points of system are fixed
from equalities as follows:
[G.sub.5] = [G.sub.6] = ([D.sub.AF]' x h)/[DELTA][h.sub.5,6]
(8)
[G.sub.7] = [G.sub.8] =
[G.sub.a]([DELTA][D.sub.9,10]/[DELTA][h.sub.11,12]) (9)
[G.sub.11] = [G.sub.12] = [D.sub.AF]'x h--Ga x
[DELTA][H.sub.9,10]/[DELTA][h.sub.11,12] (10)
[G.sub.13] = [G.sub.14] = [D.sub.AF]'x h--Ga x
[DELTA][H.sub.9,10]/[DELTA][h.sub.13,14] (11)
Quantity of heat, with which has available raw material in
characteristic points of system is determined according to equation:
[Q.sub.i] = [G.sub.i] [h.sub.i] (12)
Where i=1, 2,3,...,14 is number of characteristic points of system
whereas quantity of heat that is transmitted in exchangers of heat is:
[Q.sub.k1] = [G.sub.3] [DELTA][h.sub.3,4] = [G.sub.3] h =
[D'.sub.AF] h' (13)
[Q.sub.k2] = [G.sub.a] [DELTA][h.sub.9,10] (14)
[Q.sub.k3] = [Q.sub.k1]--[Q.sub.k2] (15)
4. CALCULATION OF PARAMETERS OF CHARACTERISTIC POINTS OF COOLING
SYSTEM
For normal work condition of furnace, value determination of
variables of cooling system (Table. 1) based in equation (1) till (15),
and accomplishes with help of appropriate program, where preliminarily
should be known input data as follows:
[t.sub.1]=[t.sub.2]=[t.sub.3]=[t.sub.4]=151,84 [degrees]C;
[t.sub.5]=[t.sub.8]=[t.sub.12]=70 [degrees]C;
[t.sub.6]=[t.sub.7]=[t.sub.11]=90 [degrees]C; [t.sub.9]=20 [degrees]C;
[t.sub.10]=80 [degrees]C; [t.sub.13]=15 [degrees]C; [t.sub.14]=50
[degrees]C; [t.sub.15]=15[degrees]C; h'=640,1 kJ/kg; H"=2749
kJ/kg; h=2109 kJ/kg; [h.sub.5]=293,2 kJ/kg; [h.sub.6]=377,1 kJ/kg;
[h.sub.7]=377,1 kJ/kg; [h.sub.8]= 293,2 kJ/kg; [h.sub.9]=19,96 kJ/kg;
[h.sub.10]=79,84 kJ/kg; [h.sub.11]=377,1 kJ/kg; [h.sub.12]=293,2kJ/kg;
[h.sub.13]=63,3 kJ/kg; [h.sub.14]=209,55 kJ/kg; [h.sub.15]=63.4 kJ/kg;
Ga=7,604 kg/s; [p.sub.1]=5,9 bar; [p.sub.2]=5 bar; [p.sub.3]=5 bar;
[p.sub.4]=5 bar; [p.sub.5]=2,5 bar; [p.sub.6]=2,25 bar; [p.sub.7]=2,25
bar; [p.sub.8]=2 bar; [p.sub.9]=1,3 bar; [p.sub.10]=1,2 bar;
[p.sub.11]=2,25 bar; [p.sub.12]=2 bar; [p.sub.13]=4 bar; [p.sub.14]=3,5
bar; [p.sub.15]=10 bar; [G.sub.0]=119,106 kg/s; [D.sub.AF]=0,375 kg/s
and [x.sub.D]=0,0031.
Gained results of variables h, [DELTA]h, G, and Q, and [Q.sub.K1],
[Q.sub.K2], [Q.sub.K3], but characteristic points of system depends on
temperature values, tensions ad appropriate enthalpies of working
mediums on system. Also are depended from factors [G.sub.o], [D.sub.AF]
and [x.sub.D], values of which are taken from preliminary calculation
which are calculated for different regimes of work in furnace and this
values mainly are depended from thermal burdens in furnace. Consequently
also quantities of heat that are transmitted in system are depended from
thermal burdens on furnace (Gordon 1993), respectively from generated
quantity of steam in furnace coolers.
5. CONCLUSION
With warming of furnace air effects of economy of fuel will achieve
for melting process in furnace for [Q.sub.K2]= 455 kW as a cause of
preliminary air warming, and decreasing of energy costs for warming of
sanitary water for [Q.sub.K3]= 336 kW, for requests of industrial
complex "Trepca". Gained data can be used for wider technical
and economic analyse for eventual applying of this cooling system.
6. REFERENCES
Sacadura, J. (1993). Knowledge for thermal transfer (Initiation aux
transferts thermiques, TEC&DOC, ISBN 2-85206-618-1, Paris.
Michael, J.; Howard, N. (2004). Fundamentals of Engineering
Thermodynamics, John Wiley, ISBN 0-471-27471-2, Hoboken.
Gordon, M. (1993). Thermal calculation of metallurgical furnace,
Metallurgy, ISBN5-229-00711-7, Moskva.
Agolli, F., (1985). Handbook of metallurgical furnace (Metalurgjia
e metaleve me ngjyra), Faculty of mining and metallurgy, Mitrovice.
Table 1. Calculated values of thermal parameters of heat bearers
t h G Q
Nr Sign oC kJ/kg kg/s kW
1 UNQ 151.54 640.10 119.11 76239.75
2 PQAU 151.54 646.64 119.11 77018.45
3 AUN 151.54 2749.00 0.38 1030.88
4 KAU 151.54 640.10 0.38 240.04
5 UFQ 70.00 293.20 9.43 2763.82
6 UNQ 90.00 377.10 9.43 3554.70
7 UNQ 90.00 377.10 5.43 2046.53
8 UNQ 70.00 293.20 5.43 1591.20
9 AFF 20.00 19.96 7.60 151.78
10 ANF 80.00 79.84 7.60 607.10
11 UNQ 90.00 377.10 4.00 1508.16
12 UFQ 70.00 293.20 4.00 1172.62
13 UFQ 15.00 63.30 2.29 145.23
14 UNS 50.00 209.55 2.29 480.78
15 UPK 15.00 63.40 0.01 0.48
Table 2. Exchanged quantity of heat in cooling system
EXCHANGERS
[K.sub.1] [K.sub.2] [K.sub.3]
[Q.sub.K1] [kW] [Q.sub.K2] [kW] [Q.sub.K3] [kW]
791 455 336