首页    期刊浏览 2024年09月20日 星期五
登录注册

文章基本信息

  • 标题:熱イオン化検出器付ガスクロマトグラフィーによるラット尿中メタンフェタミンとその代謝産物の一斉高感度分析
  • 本地全文:下载
  • 作者:寺田 賢 ; 吉村 三郎 ; 山元 俊憲
  • 期刊名称:Journal of Health Science
  • 印刷版ISSN:1344-9702
  • 电子版ISSN:1347-5207
  • 出版年度:1983
  • 卷号:29
  • 期号:3
  • 页码:143-153
  • DOI:10.1248/jhs1956.29.3_143
  • 出版社:The Pharmaceutical Society of Japan
  • 摘要:A rapid and simple procedure for the determinaion of methamphetamine and its metabolites in the rat urine was described by using gas chromatography with flame-thermoionic detector. The extraction procedure, the formation of heptafluorobutyryl derivative, the percentage recovery of the methamphetamine and its metabolites from the rat urine and the determination of methamphetamine metabolites in the rat urine were described. The sensitivity of methamphetamine and its metabolites by gas chromatography with flamethermoionic detector revealed that the detection limits of heptafluorobutyryl derivatives of methamphetamine and amphetamine were ca. 0.1 ng, p-hydroxyamphetamine and p-hydroxymethamphetamine were 0.14, 0.16 ng, respectively, norephedrine and p-hydroxynorephedrine were 0.26, 1.04 ng, respectively. In the rats, about 89% of the dose of methamphetamine (2.5 mg/kg, i.p.) and 74% of the dose of methamphetamine (5.0 mg/kg, i.p.) were excreted in the 2 days urine. The main metabolites excreted in the urine were p-hydroxymethamphetamine (56-47% of dose), p-hydroxyamphetamine (21-15% of dose) and amphetamine (2.7-3.3% of dose) in addition to the unchanged methamphetamine (9.0-8.6% of dose). The gas chromatography equipped with flame-thermoionic detector used for the determination of methamphetamine and its metabolites in the rat urine was satisfactory, and rapid, simple and highly sensitive method, and thus the method would be applicable for the determination of those drugs in the urine of the abusers.
  • 关键词:methamphetamine;methamphetamine metabolites;rat urine;GC;flame-thermoionic detector;GC-MS;heptafluorobutyryl derivatives
国家哲学社会科学文献中心版权所有