首页    期刊浏览 2024年11月07日 星期四
登录注册

文章基本信息

  • 标题:The Result of Using an Additional Mini-Locking Plate for Tibial Pilon Fractures
  • 本地全文:下载
  • 作者:Jo, Suenghwan ; Lee, Jun Young ; Kim, Boseon
  • 期刊名称:Journal of the Korean Fracture Society
  • 印刷版ISSN:1225-1682
  • 出版年度:2017
  • 卷号:30
  • 期号:2
  • 页码:75-82
  • DOI:10.12671/jkfs.2017.30.2.75
  • 语种:Korean
  • 出版社:The Korean Fracture Society
  • 摘要:Purpose

    We evaluated the usefulness of an additional, 2.7 mm mini-locking plate for tibial pilon fractures.

    Materials and Methods

    We studied 21 patients (14 males and 7 females), who were treated with a 2.7 mm mini-locking plate via the anterolateral approach for tibial pilon fractures between September 2012 and April 2014. The mean age was 43.85 years, and the mean follow-up period was 16.6 months. The radiologic outcomes were graded by the Burwell and Charnley modified system and clinical outcomes were evaluated by the American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hind foot score and visual analogue scale (VAS) score.

    Results

    The mean union period was 14.3 weeks. At the final follow-up, radiologic results showed 16 excellent results, 4 fair results, and 1 poor result. The average VAS was 3.4 points; the average AOFAS score was 81.8 points. During the follow-up period, there were three cases of posttraumatic osteoarthritis and one case of superficial skin infection.

    Conclusion

    Additional anterolateral, 2.7 mm mini-locking plate may be a good treatment method to manage tibial pilon fractures.

  • 关键词:Distal tibia fracture; Tibia plafond fracture; Pilon fracture; locking plate
国家哲学社会科学文献中心版权所有