首页    期刊浏览 2024年08月31日 星期六
登录注册

文章基本信息

  • 标题:Possible Risk Factors Affecting Successful Femtosecond Laser-assisted Cataract Surgery
  • 本地全文:下载
  • 作者:Yang, Heon ; Han, Sang Youp ; Lee, Kyung Heon
  • 期刊名称:Journal of the Korean Ophthalmological Society
  • 印刷版ISSN:0378-6471
  • 出版年度:2017
  • 卷号:58
  • 期号:5
  • 页码:539-545
  • DOI:10.3341/jkos.2017.58.5.539
  • 语种:Korean
  • 出版社:The Korean Ophthalmological Society
  • 摘要:Purpose

    To determine the risk factors of intraoperative complications in femtosecond laser-assisted cataract surgery.

    Methods

    This study included 598 eyes of 337 patients who underwent femtosecond laser-assisted cataract surgery (FLACS) between July, 2012 and January, 2017. All eyes had corneal incisions, anterior capsulotomy, nuclear fragmentation, and limbal relaxing incisions (if required). Intraoperative complications were analyzed by watching videos, and the related factors of each complication were retrospectively reviewed alongside the medical records.

    Results

    The mean age of the patients was 62.1 ± 11.9 years. Among the study group, 18 eyes required manual creation of corneal incisions; because the corneal incisions could not be made due to corneal central opacity, corneal peripheral degeneration, ptreygium, conjunctival chalasis, or idiopathic. The anterior capsulotomy was incomplete in 43 cases and manual capsulorrhexis was required for completion. These cases were associated with various conditions, including hypermature cataract, anterior polar or subcapsular cataract, corneal central opacity, pupillary abnormality, lens subluxation, poor pupil dilation, and idiopathic. Overall, 22 eyes had difficulties with nuclear fragmentation, with either mature cataract, lens subluxation, corneal central opacity, anterior polar or subcapsular cataract, or pupillary abnormality. Using the Laser SoftFit™ patient interface decreased the incidences of incomplete corneal incision (from 3.56% to 2.24%, p = 0.367), anterior capsulotomy (from 9.31% to 4.03%, p < 0.05), and nuclear fragmentation (from 5.20% to 1.34%, p < 0.05). The incidences of complications in the experienced group was statistically lower compared with the novice group ( p < 0.05 for all comparisons).

    Conclusions

    The femtosecond laser platform was effective and safe for cataract surgery. However, in the presence of related factors, use of this platform might need to be re-assessed and should be considered for intraoperative complications. Additionally, with the Laser SoftFit™ patient interface and improved surgeon experience, better intraoperative results can be expected for FLACS surgery.

  • 关键词:Anterior capsulotomy; Corneal incision; Femtosecond cataract surgery; Nuclear fragmentation; Related factors
国家哲学社会科学文献中心版权所有