首页    期刊浏览 2025年07月14日 星期一
登录注册

文章基本信息

  • 标题:A Novel Surface Plasmon Resonance Biosensor for the Rapid Detection of Botulinum Neurotoxins
  • 本地全文:下载
  • 作者:Kruti Patel
  • 期刊名称:Biosensors
  • 电子版ISSN:2079-6374
  • 出版年度:2017
  • 卷号:7
  • 期号:3
  • 页码:32
  • DOI:10.3390/bios7030032
  • 语种:English
  • 出版社:MDPI Publishing
  • 摘要:Botulinum neurotoxins (BoNTs) are Category A agents on the NIAID (National Institute of Allergy and Infectious Diseases) priority pathogen list owing to their extreme toxicity and the relative ease of production. These deadly toxins, in minute quantities (estimated human i.v. lethal dose LD50 of 1–2 ng/kg body weight), cause fatal flaccid paralysis by blocking neurotransmitter release. The current gold standard detection method, the mouse-bioassay, often takes days to confirm botulism. Furthermore, there are no effective antidotes known to reverse the symptoms of botulism, and as a result, patients with severe botulism often require meticulous care during the prolonged paralytic illness. To combat potential bio-terrorism incidents of botulinum neurotoxins, their rapid detection is paramount. Surface plasmon resonance (SPR) is a very sensitive technique to examine bio-molecular interactions. The label-free, real-time analysis, with high sensitivity and low sample consumption makes this technology particularly suitable for detection of the toxin. In this study, we demonstrated the feasibility in an assay with a newly designed SPR instrument for the rapid detection of botulinum neurotoxins. The LOD (limit of detection) of the Newton Photonics (NP) SPR based assay is 6.76 pg/mL for Botulinum Neurotoxin type A Light Chain (BoNT/A LC). We established that the detection sensitivity of the system is comparable to the traditional mouse LD50 bioassay in BoNT/A using this SPR technology.
  • 关键词:biosensor; botulinum; clostridium; rapid detection; surface plasmon resonance biosensor ; botulinum ; clostridium ; rapid detection ; surface plasmon resonance
国家哲学社会科学文献中心版权所有